"SMART-Seq Ultra Low Input: Single cell sequencing (´ÜÀϼ¼Æ÷ ¿°±â¼­¿­ ºÐ¼®) ³í¹®¸®½ºÆ® º¸±â"

* ´õ ³ôÀº È¿À²À» º¸À¯ÇÑ ¾÷±×·¹À̵å Á¦Ç°, SMARTer Ultra Low Input RNA Kit for Sequencing - v3 »ç¿ëÀ» ÃßõÇÕ´Ï´Ù.

SMARTer Ultra Low RNA Kit for Illumina¢ç Sequencing-HVÀº ¸Å¿ì ¼Ò·®ÀÇ total RNA(10pg-10 ng)³ª ¼Ò·®ÀÇ ¼¼Æ÷(1-1000 cells)¸¦ ÀÌ¿ëÇÏ¿© °ð¹Ù·Î transcriptome ºÐ¼®(RNA-seq)¿¡ ÀÌ¿ëÇÒ ¼ö ÀÖ´Â library¸¦ Á¦ÀÛ ÇÒ ¼ö ÀÖ´Â cDNAÇÕ¼ºÀÌ °¡´ÉÇÏ´Ù. ÇÕ¼ºµÈ cDNA´Â Nextera¢ç DNA sample preparation kit (using our modified protocol) ¶Ç´Â ThruPLEX¢ç DNA-seq Kit (Code R400523)¸¦ ÀÌ¿ëÇÏ¿© Illumina's Genome Analyzer¢â, HiSeq¢ç, ¶Ç´Â MiSeq¢ç instrument¿¡ Àû¿ë ÇÒ ¼ö ÀÖ´Â library¸¦ Á¦ÀÛ ÇÒ ¼ö ÀÖ´Ù.

SMARTer Ultra Low RNA Kit for Illumina¢ç Sequencing-HVÀº oligo dT priming ¹æ¹ýÀ» ÀÌ¿ëÇÏ¿© high quality RNA (RIN >8)³ª intact cellsÀ» ÀÌ¿ëÇÑ´Ù. ±âÁ¸ÀÇ SMARTer Ultra Low RNA Kit for Illumina Sequencing(maximum input volume=1 ¥ìl) ¿¡¼­ input volumeÀÌ 1-9 ul·Î modifyµÈ ÇÁ·ÎÅäÄÝÀ» ÀÌ¿ëÇÑ´Ù. º¯ÇüµÈ input volumeÀº Èñ¼®µÈ »ùÇÃÀ̳ª large volume¿¡ µé¾îÀÖ´Â sorted cellÀ» ÀÌ¿ëÇÒ ¶§ À¯¿ëÇÏ´Ù.

±×¸²1. Overview of SMARTer Ultra Low RNA Kit sample preparation for Illumina sequencing
Ư¡

±×¸²2. Electropherogram of amplified SMARTer cDNA. Various amounts of Universal Human Reference Total RNA (UHR) and Human Brain Reference RNA were used as input for SMARTer cDNA synthesis.The cDNA samples were then analyzed for purity and yield on an Agilent 2100 Bioanalyzer. Shown are Bioanalyzer trace overlays of cDNA amplified from 1 ng (red line), 0.1 ng (dark blue line), 0.05 ng (green line), and 0.01 ng (light blue line) of total RNA and a no template control (NTC; pink line). The main peak indicates the purity and yield of cDNA between 0.4 and 9 kb with the highest point at ~2 kb. There was no amplification in the negative control (pink line). Although the amount of input RNA can vary over quite a large range (e.g., 1 ng to 0.01 ng), comparable cDNA output can be obtained by adjusting the number of PCR cycles.


±×¸² 3. Gene expression data obtained from very low amounts of RNA correlate well with data obtained by qPCR. Scatter plots were used to compare differential expression data obtained by sequencing with the SMARTer Ultra Low RNA Kit (1 ng total RNA) and quantitative PCR (qPCR) data available for Universal Human Reference Total RNA (UHR) and Human Brain Reference RNA through the MicroArray Quality Control (MAQC) project. The differential expression of ~700 genes showed correlation values of 0.94, demonstrating that the sequencing results are consistent with orthogonal gene expression technologies.



±×¸² 4. Comparison of transcript coverage with different amounts of input RNA. Shown are overlaid plots comparing the average read coverage from libraries made with 1 ng to 0.01 ng of mouse brain total RNA. The x-axis represents gene length normalized to 100%, where 0 is the 5'-end of each transcript and 100 is the 3'-end. The y-axis indicates the average coverage for a set of 724 genes that are moderately to highly expressed in brain tissue. The results are very consistent through the range of input RNA used, with full-length coverage of the transcripts reflecting no systematic 5'- or 3'-bias.
±¸¼ºÇ° (ÀÚ¼¼ÇÑ ³»¿ëÀº CoA¸¦ ÂüÁ¶Çϼ¼¿ä)
* SMARTer Ultra Low Input RNA for Illumina Sequencing Components - HV
* Advantage 2 PCR Kit (Cat. No. 639207)